Riello Sentinel Dual (Low Power) (SDH 2200 ER) On Line UPS

Free shipping
Save 15%
Ask a question
10915
upon order
Online UPS The Sentinel Dual series is the new series of high power density double conversion online UPS and is suitable for powering a wide range of devices such as servers, storage systems, telephony - VoIP equipment, networks, medical systems as well as for industrial applications. It...
1,040.00 
884.00 
(1,096.16  inc tax) You save: 156.00 
+
Shipment

All Around Greece

Payment
Do you have questions?

Online UPS
The Sentinel Dual series is the new series of high power density double conversion online UPS and is suitable for powering a wide range of devices such as servers, storage systems, telephony - VoIP equipment, networks, medical systems as well as for industrial applications.

It is also ideal for powering and protecting Blade Server systems with high input power factor. At just 2U, the Sentinel Dual is ideal for installation in a 19″ rack cabinet. The Sentinel Dual has a practical, modern design and has several advantages over traditional on-line UPS.

It has been developed entirely by the Riello UPS R&D team. The newly designed inverter is one of the best energy conversion systems on the market, with a power factor of 0.9 output and an efficiency of 92% in on-line mode.

For professional applications that require continuity of electricity and need long autonomy times, the autonomy of the batteries can be extended up to several hours by using the ER models which are equipped with powerful battery chargers.

With energy conservation in mind, the Sentinel Dual series features a stop button to reduce power consumption to zero during periods of prolonged inactivity.

Easy installation

Low noise (Guaranteed operation up to 40 ° C (components are designed for high temperatures and therefore subject to less stress at normal temperatures)
On Sentinel Dual Series models, the outlet receptacles can be programmed to disconnect less critical loads during a power outage (EnergyShare outlets).
Flexible installation
The Sentinel Dual can be placed as a tower or rack, the screen rotates easily and you can place it in a vertical form (tower) with the provided bases.

Reduced operating costs
The UPS has particularly flexible and easy settings. Programmable functions can be set through the software or manually from the display panel. Sentinel Dual can be configured in the following modes:

On Line, maximum load protection and high quality output voltage waveform
ECO mode, to increase efficiency (up to 98%), uses Line Interactive technology
Smart Active, the UPS automatically selects the operating program according to the quality of the mains power supply
Emergency, the UPS only works when the mains voltage is interrupted (emergency mode)
Operation as a frequency converter (50 or 60 Hz).
Advanced Communications

The advanced communication platform is compatible with all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows 8, 7, Hyper-V, 2012, 2008, and earlier operating systems, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems.
RS232 serial port and optically isolated contacts
USB port
Socket for communication cards such as Modbus / Jbus, TCP / IP, SNMP and relay contacts.
High quality output voltage

Even with non-linear loads (IT loads with peak factor up to 3:1)
High short circuit current in bypass circuit
High overload capacity: 150% from inverter (even with mains failure)
Filtered, stabilized and reliable electricity using On-line double conversion technology (VFI compliant to EN62040-2 class C2) with filters to suppress atmospheric disturbances
Power factor correction: the input power factor of the UPS is close to 1 and the current absorption is sinusoidal.
High battery reliability

Automatic and manual battery control
Accumulators can be replaced without turning off the equipment and without interrupting the supply to the load (Hot Swap)
Unlimited range time extension using compatible battery packs.
Important features

Output voltage can be selected via software (220-230-240 V)
Automatic restart when the power grid is restored (programming via software)
Stand-by on bypass: when the machine is switched off, it automatically goes into bypass mode and charges the batteries
Minimum shutdown load at low load
Operating status, readings and notifications are displayed on the backlit screen
Update UPS software via PC
Manual switching to bypass line
Sentinel Dual (Low Power): No built-in batteries, with additional built-in 8A charger

Riello Sentinel Dual (Low Power) (SDH 1000) On Line UPS
Free shipping
Save 15%
10912
1-3 Days
677.00  575.45 
(713.56  inc tax)
Riello Sentinel Dual (Low Power) (SDH 1500) On Line UPS
Free shipping
Save 15%
10913
1-3 Days
804.00  683.40 
(847.42  inc tax)
Riello Sentinel Dual (Low Power) (SDH 2200) On Line UPS
Free shipping
Save 15%
10914
1-3 Days
1,020.00  867.00 
(1,075.08  inc tax)
Riello Sentinel Dual (Low Power) (SDH 3000 ER) On Line UPS
Free shipping
Save 15%
10917
upon order
1,123.00  954.55 
(1,183.64  inc tax)
Possibly you may be interested
  • Bestsellers
  • Most Popular
Instant delivery

All Around Greece

Product Warranty

We Offer best products

Return Policy

See more